EMP Pulse Blaster: Difference between revisions
From FusionGirl Wiki
Jump to navigationJump to search
No edit summary |
No edit summary |
||
Line 18: | Line 18: | ||
== Equations == | == Equations == | ||
* | * ``Energy Density**: The energy density of the electromagnetic field. | ||
** <math>E = \frac{{B^2}}{{2 \mu_0}}</math> | ** <math>E = \frac{{B^2}}{{2 \mu_0}}</math> | ||
*** Where: | *** Where: | ||
Line 25: | Line 25: | ||
**** <math>\mu_0</math> is the permeability of free space (<math>4\pi \times 10^{-7}</math> H/m) | **** <math>\mu_0</math> is the permeability of free space (<math>4\pi \times 10^{-7}</math> H/m) | ||
* | * ``Volume of a Sphere**: Used to calculate the volume of the area affected by the EMP. | ||
** <math>V = \frac{4}{3} \pi r^3</math> | ** <math>V = \frac{4}{3} \pi r^3</math> | ||
*** Where: | *** Where: | ||
Line 31: | Line 31: | ||
**** <math>r</math> is the radius of the sphere in meters (m) | **** <math>r</math> is the radius of the sphere in meters (m) | ||
* | * ``Power Output (General)**: The power output during the EMP pulse. | ||
** <math>\text{Power Output} = \frac{\text{Total Energy Output}}{\text{Pulse Duration}}</math> | ** <math>\text{Power Output} = \frac{\text{Total Energy Output}}{\text{Pulse Duration}}</math> | ||
*** Where: | *** Where: | ||
Line 38: | Line 38: | ||
**** Pulse Duration is in seconds (s) | **** Pulse Duration is in seconds (s) | ||
* | * ``Capacitor Energy Storage**: The energy stored in a capacitor. | ||
** <math>E = \frac{1}{2} CV^2</math> | ** <math>E = \frac{1}{2} CV^2</math> | ||
*** Where: | *** Where: | ||
Line 45: | Line 45: | ||
**** <math>V</math> is the voltage in volts (V) | **** <math>V</math> is the voltage in volts (V) | ||
* | * ``Inductance of a Coil**: The inductance of a coil used in the EMP generator. | ||
** <math>L = \frac{N^2 \mu_0 \mu_r A}{l}</math> | ** <math>L = \frac{N^2 \mu_0 \mu_r A}{l}</math> | ||
*** Where: | *** Where: | ||
Line 55: | Line 55: | ||
**** <math>l</math> is the length of the coil in meters (m) | **** <math>l</math> is the length of the coil in meters (m) | ||
* | * ``Magnetic Flux**: The magnetic flux through a coil. | ||
** <math>\Phi = B A \cos(\theta)</math> | ** <math>\Phi = B A \cos(\theta)</math> | ||
*** Where: | *** Where: | ||
Line 63: | Line 63: | ||
**** <math>\theta</math> is the angle between the magnetic field and the normal to the surface | **** <math>\theta</math> is the angle between the magnetic field and the normal to the surface | ||
* | * ``Faraday’s Law of Induction**: The induced voltage in a coil. | ||
** <math>V = -N \frac{d\Phi}{dt}</math> | ** <math>V = -N \frac{d\Phi}{dt}</math> | ||
*** Where: | *** Where: | ||
Line 70: | Line 70: | ||
**** <math>\frac{d\Phi}{dt}</math> is the rate of change of magnetic flux in webers per second (Wb/s) | **** <math>\frac{d\Phi}{dt}</math> is the rate of change of magnetic flux in webers per second (Wb/s) | ||
* | * ``Resonant Frequency of LC Circuit**: The frequency at which the LC circuit resonates. | ||
** <math>f_0 = \frac{1}{2\pi\sqrt{LC}}</math> | ** <math>f_0 = \frac{1}{2\pi\sqrt{LC}}</math> | ||
*** Where: | *** Where: | ||
Line 77: | Line 77: | ||
**** <math>C</math> is the capacitance in farads (F) | **** <math>C</math> is the capacitance in farads (F) | ||
* | * ``Magnetic Field of a Solenoid**: The magnetic field inside a solenoid. | ||
** <math>B = \mu_0 \frac{N}{l} I</math> | ** <math>B = \mu_0 \frac{N}{l} I</math> | ||
*** Where: | *** Where: | ||
Line 86: | Line 86: | ||
**** <math>I</math> is the current in amperes (A) | **** <math>I</math> is the current in amperes (A) | ||
* | * ``Heat Dissipation in Resistors**: The power dissipated as heat in a resistor. | ||
** <math>P = I^2 R</math> | ** <math>P = I^2 R</math> | ||
*** Where: | *** Where: | ||
Line 93: | Line 93: | ||
**** <math>R</math> is the resistance in ohms (Ω) | **** <math>R</math> is the resistance in ohms (Ω) | ||
* | * ``Ohm’s Law**: The relationship between voltage, current, and resistance. | ||
** <math>V = IR</math> | ** <math>V = IR</math> | ||
*** Where: | *** Where: | ||
Line 100: | Line 100: | ||
**** <math>R</math> is the resistance in ohms (Ω) | **** <math>R</math> is the resistance in ohms (Ω) | ||
* | * ``Electromagnetic Wave Equation**: Describes the propagation of electromagnetic waves. | ||
** <math>\nabla^2 \mathbf{E} - \mu_0 \epsilon_0 \frac{\partial^2 \mathbf{E}}{\partial t^2} = 0</math> | ** <math>\nabla^2 \mathbf{E} - \mu_0 \epsilon_0 \frac{\partial^2 \mathbf{E}}{\partial t^2} = 0</math> | ||
*** Where: | *** Where: | ||
Line 110: | Line 110: | ||
== Components == | == Components == | ||
* | * ``Energy Storage and Management`` | ||
** Super Capacitors | ** Super Capacitors | ||
*** Capacitor Cells | *** Capacitor Cells | ||
Line 122: | Line 122: | ||
***** Rapid release of stored energy | ***** Rapid release of stored energy | ||
* | * ``High-Voltage Generation`` | ||
** High-Voltage Generators | ** High-Voltage Generators | ||
*** Transformer | *** Transformer | ||
Line 137: | Line 137: | ||
***** Switching Transistors | ***** Switching Transistors | ||
* | * ``Electromagnetic Field Creation`` | ||
** Coils | ** Coils | ||
*** Wire | *** Wire | ||
Line 156: | Line 156: | ||
**** Shielding Material | **** Shielding Material | ||
* | * ``Pulse Control and Modulation`` | ||
** Pulse Control Circuitry | ** Pulse Control Circuitry | ||
*** Timing Circuit | *** Timing Circuit | ||
Line 167: | Line 167: | ||
**** Resistors | **** Resistors | ||
* | * ``Power Supply`` | ||
** Batteries | ** Batteries | ||
*** Battery Cells | *** Battery Cells | ||
Line 178: | Line 178: | ||
**** Fuses | **** Fuses | ||
* | * ``Safety and Regulatory Compliance`` | ||
** Safety Features | ** Safety Features | ||
*** Overcurrent Protection | *** Overcurrent Protection | ||
Line 189: | Line 189: | ||
**** Safety Relays | **** Safety Relays | ||
* | * ``Wire Gauge and Thermal Management`` | ||
** Wire | ** Wire | ||
** Heat Sinks | ** Heat Sinks | ||
Line 199: | Line 199: | ||
**** Thermal Cutoffs | **** Thermal Cutoffs | ||
* | * ``Integration and Compatibility`` | ||
** Connectors | ** Connectors | ||
** Mounting Hardware | ** Mounting Hardware | ||
Line 211: | Line 211: | ||
== Safety and Regulatory == | == Safety and Regulatory == | ||
* | * ``Safety Features`` | ||
** Overcurrent Protection | ** Overcurrent Protection | ||
** Voltage Regulation | ** Voltage Regulation |
Revision as of 15:18, 15 May 2024
Electro Magnetic Pulse - Pulse Blaster
Parameters
Parameter | Value/Equation |
---|---|
Range (r) | 13 meters |
Energy Density | to joules/m |
Total Energy Output | joules |
Voltage Output (High-Voltage Generator Modules) | 3000V, 4000V, 400kV, 1MV |
Equations
- ``Energy Density**: The energy density of the electromagnetic field.
-
- Where:
- is the energy density in joules per cubic meter (J/m)
- is the magnetic flux density in teslas (T)
- is the permeability of free space ( H/m)
- Where:
-
- ``Volume of a Sphere**: Used to calculate the volume of the area affected by the EMP.
-
- Where:
- is the volume in cubic meters (m)
- is the radius of the sphere in meters (m)
- Where:
-
- ``Power Output (General)**: The power output during the EMP pulse.
-
- Where:
- Power Output is in watts (W)
- Total Energy Output is in joules (J)
- Pulse Duration is in seconds (s)
- Where:
-
- ``Capacitor Energy Storage**: The energy stored in a capacitor.
-
- Where:
- is the energy stored in joules (J)
- is the capacitance in farads (F)
- is the voltage in volts (V)
- Where:
-
- ``Inductance of a Coil**: The inductance of a coil used in the EMP generator.
-
- Where:
- is the inductance in henries (H)
- is the number of turns
- is the permeability of free space ( H/m)
- is the relative permeability of the core material
- is the cross-sectional area of the coil in square meters (m)
- is the length of the coil in meters (m)
- Where:
-
- ``Magnetic Flux**: The magnetic flux through a coil.
-
- Where:
- is the magnetic flux in webers (Wb)
- is the magnetic flux density in teslas (T)
- is the area in square meters (m)
- is the angle between the magnetic field and the normal to the surface
- Where:
-
- ``Faraday’s Law of Induction**: The induced voltage in a coil.
-
- Where:
- is the induced voltage in volts (V)
- is the number of turns
- is the rate of change of magnetic flux in webers per second (Wb/s)
- Where:
-
- ``Resonant Frequency of LC Circuit**: The frequency at which the LC circuit resonates.
-
- Where:
- is the resonant frequency in hertz (Hz)
- is the inductance in henries (H)
- is the capacitance in farads (F)
- Where:
-
- ``Magnetic Field of a Solenoid**: The magnetic field inside a solenoid.
-
- Where:
- is the magnetic field in teslas (T)
- is the permeability of free space ( H/m)
- is the number of turns
- is the length of the solenoid in meters (m)
- is the current in amperes (A)
- Where:
-
- ``Heat Dissipation in Resistors**: The power dissipated as heat in a resistor.
-
- Where:
- is the power in watts (W)
- is the current in amperes (A)
- is the resistance in ohms (Ω)
- Where:
-
- ``Ohm’s Law**: The relationship between voltage, current, and resistance.
-
- Where:
- is the voltage in volts (V)
- is the current in amperes (A)
- is the resistance in ohms (Ω)
- Where:
-
- ``Electromagnetic Wave Equation**: Describes the propagation of electromagnetic waves.
-
- Where:
- is the electric field in volts per meter (V/m)
- is the permeability of free space ( H/m)
- is the permittivity of free space ( F/m)
- is the time in seconds (s)
- Where:
-
Components
- ``Energy Storage and Management``
- Super Capacitors
- Capacitor Cells
- Connecting Wires
- SubModules
- Capacitor Bank
- Multiple super capacitors connected in series or parallel
- Charging Circuit
- Ensures capacitors are charged safely and efficiently
- Discharge Mechanism
- Rapid release of stored energy
- Capacitor Bank
- Super Capacitors
- ``High-Voltage Generation``
- High-Voltage Generators
- Transformer
- Rectifier Circuit
- Switching Mechanism
- SubModules
- Control Unit
- Microcontroller or PLC for managing switching
- Voltage Multiplier
- Series of capacitors and diodes to increase voltage
- SubComponents
- Inductor Coils
- Diodes
- Switching Transistors
- Control Unit
- High-Voltage Generators
- ``Electromagnetic Field Creation``
- Coils
- Wire
- Core Material
- SubModules
- Primary Coil
- Secondary Coil
- SubComponents
- Insulation Material
- Mounting Brackets
- Magnet Arrays
- Magnets
- Magnet Holders
- SubModules
- Focusing Array
- Blocking Array
- SubComponents
- Shielding Material
- Coils
- ``Pulse Control and Modulation``
- Pulse Control Circuitry
- Timing Circuit
- Modulation Unit
- SubModules
- Oscillator
- Amplifier
- SubComponents
- Capacitors
- Resistors
- Pulse Control Circuitry
- ``Power Supply``
- Batteries
- Battery Cells
- Battery Management System (BMS)
- SubModules
- Charging Circuit
- Protection Circuit
- SubComponents
- Thermal Sensors
- Fuses
- Batteries
- ``Safety and Regulatory Compliance``
- Safety Features
- Overcurrent Protection
- Voltage Regulation
- SubModules
- Circuit Breakers
- Surge Protectors
- SubComponents
- Insulation Materials
- Safety Relays
- Safety Features
- ``Wire Gauge and Thermal Management``
- Wire
- Heat Sinks
- SubModules
- Cooling Fans
- Thermal Paste
- SubComponents
- Temperature Sensors
- Thermal Cutoffs
- ``Integration and Compatibility``
- Connectors
- Mounting Hardware
- SubModules
- Interface Boards
- Compatibility Testing Units
- SubComponents
- Screws and Fasteners
- Alignment Tools
Safety and Regulatory
- ``Safety Features``
- Overcurrent Protection
- Voltage Regulation
- Insulation Monitoring
Additional Considerations
- Wire Gauge: Determine based on current and temperature rise.
- Amps and Volts: Dependent on design and requirements.
- Efficiency and Losses: Consider efficiency of components and system.
- Integration and Compatibility: Ensure compatibility and effective integration of components.
- Environmental Factors: Consider atmospheric conditions and electromagnetic interference.
Assembly and Testing
- Assemble Super Capacitor Bank and High-Voltage Generators
- Integrate Coils and Magnet Arrays with High-Voltage Output
- Install Pulse Control Circuitry and Battery System
- Implement Safety Features and Thermal Management
- Perform Integration Testing to Ensure Compatibility and Performance
- Conduct Safety Testing to Ensure Compliance with Regulatory Standards